当前位置:首页 > 过刊浏览->2019年40卷第11期
某超(超)临界锅炉温度套管失效原因分析
Failure Reason Analysis of Temperature Casing in Supercritical/Ultra Supercritical Boiler
浏览(102) 下载(0)
- DOI:
- 作者:
- 李鹏刚1,王 强2
LI Penggang1, WANG Qiang2
- 作者单位:
- 1. 华电电力科学研究院有限公司,浙江杭州313300;2.西安热工研究院有限公司,陕西西安710054
1. Huadian Electric Power Research Institute Co., Ltd., Hangzhou 313300, China; 2. Xi’an Thermal Power Research Institute Co., Ltd., Xi’an 710054, China
- 关键词:
- 温度套管;断裂;失效;疲劳;裂纹
temperature casing; fracture; failure; fatigue; crack
- 摘要:
- 为了解超(超)临界锅炉温度套管断裂原因,采用宏观检查、化学成分分析、金相检验、硬度测量、断口形貌 分析、ANSYS有限元分析,对断裂温度套管的失效原因进行了分析。结果表明,温度套管在交变应力作用下萌生疲劳裂 纹,并不断扩展,最终导致套管断裂。In order to understand the fracture reason of the temperature sleeve of the supercritical boiler, the failure reason of the temperature sleeve of the supercritical boiler was analyzed by means of macroscopic examination, chemical composition analysis, metallographic examination, hardness measurement, fracture morphology analysis and ANSYS finite element analysis. The results show that the fatigue crack of the temperature casing is initiated under the action of alternating stress, and the fatigue crack is extended continuously, which finally causes the casing fracture.